【节能学院】安科瑞医疗IT产品在彭世洛医院项目的设计与应用

江苏安科瑞电器制造有限公司 2022-01-18 09:46 次阅读

摘要:随着电子医疗设备在医院领域的广泛应用,漏电流对病人构成的威胁也越来越大,尤其是那些生命攸关的场所,病人在手术中或麻醉状态下,各种电极、传感器直接插入人体内,微小的漏电流都有可能导致病人触电身亡。另外有些医疗设备用于维持重症病人的生命,一旦设备停电,也会对病人的生命构成威胁。因此,对于医院这一特殊场所的电气设计,应严格按照国家标准和规范要求,采用IT系统供电。本文介绍了医疗IT在彭世洛医院的应用。

Abstract: With the widespread application of electronic medical equipment in hospitals, the threat of leakage current to patients is becoming greater and greater, especially in places where life is critical. The patients are directly exposed to various electrodes and sensors during surgery or anesthesia. Inserted into the human body, even the slight leakage current may cause the patient to be electrocuted. In addition, some medical equipment is used to maintain the lives of critically ill patients. Once the equipment is powered off, it will also threaten the lives of patients. Therefore, for the electrical design of the special place of the hospital, the IT system should be used for power supply in strict accordance with national standards and regulations.This article introduces the application of Medical isolated power supply in Pitsanulok hospital project.

关键字:医疗IT,绝缘监测仪

Keywords:Medical IT, Insulation monitor device

0

项目概况 Project overview

彭世洛医院位于泰国彭世洛,本次项目主要用于彭世洛医院医疗设备升级。

Pitsanulok hospital project is located in Thailand,the project is mainly used for Pitsanulok hospital medical equipment update.

1

项目背景Background

配电系统引起的触电和系统故障大多是设备线路接地故障引起的。接地故障会直接带来供电中断的危害;接地故障漏电严重时,甚至会烧毁电气设备或线路,造成无法弥补的损失。

在医疗场所,特别是那些危及生命的二级医疗场所,处于手术或麻醉状态的患者,没有自我行为能力,小漏电流可导致患者触电死亡。因此,该特殊场所的电气设计应严格按照国家有关标准和规范进行。

Electric shock and system fault caused by power distribution system are mostly caused by the grounding fault of equipment line. Grounding fault will directly bring the harm of power supply interruption; when the earth fault leakage is serious, it will even burn electrical equipment or lines, causing irreparable loss.

In Medical places, especially those life-threatening class 2 medical places, patients in surgery or anesthesia state, without self-behavior ability, small leakage current can lead to electric shock death of patients. Therefore, the electrical design of this special place should be carried out strictly in accordance with the relevant national standards and specifications.

84ae7722-77b4-11ec-9437-dac502259ad0.png

IT配电系统(又称隔离供电系统或不接地系统)由于其中性点不接地,对地漏电流非常小。发生第一次绝缘故障时,不会影响设备的供电。所以系统可以继续运行。安装在系统中的绝缘监测装置可以及时发现故障并发出相应的故障警告,提示相关人员在适当的时候排除故障。对于手术室、重症监护室等对供电连续性和安全性要求较高的医疗场所,本地IT系统供电可以保证重要负载供电的安全性和可靠性。

IT power distribution system (also known as isolated power supply system or ungrounded system) has very small leakage current to ground due to its neutral point ungrounded. When the first insulation fault occurs, the power supply of the equipment will not be affected. So the system can continue to operate. The insulation monitoring device installed in the system can detect the fault in time and send out the corresponding fault warning, prompting the relevant personnel to remove the fault at the appropriate time. For the operation room, intensive care unit and other medical places with high requirements for power supply continuity and safety, local IT system power supply can ensure the security and reliability of power supply for important loads.

84f2fd5c-77b4-11ec-9437-dac502259ad0.png

2

医疗IT五件套

Five sets of medical IT products

医疗IT系统绝缘监测与故障定位产品(五件套)包括AITR系列医用隔离变压器、AIM-M100医用智能绝缘监测仪、AKH-0.66P26电流互感器、ACLP10-24直流电源、AID系列(AID120 /AID150)集中报警显示仪表,如表1所示。

表1 医疗IT系统绝缘监测产品

85378d82-77b4-11ec-9437-dac502259ad0.png8567cde4-77b4-11ec-9437-dac502259ad0.png

Medical IT system insulation monitoring and fault locating products (five-piece set) include AITR series medical isolation transformer, AIM-M100 medical intelligent insulation monitoring instrument, AKH-0.66P26 current transformer, ACLP10-24 DC power supply, and AID series(AID120/AID150) centralized alarm and display instrument, which are shown in Table 1.

Table 1

Medical IT System Insulation Monitoring Products

8591dbf2-77b4-11ec-9437-dac502259ad0.png86006284-77b4-11ec-9437-dac502259ad0.png8647f158-77b4-11ec-9437-dac502259ad0.png

3

现场图片 On site Photos

869255d6-77b4-11ec-9437-dac502259ad0.jpg86ca43ba-77b4-11ec-9437-dac502259ad0.jpg86f81da8-77b4-11ec-9437-dac502259ad0.png

请旋转手机

查看更多精彩

点我

87234758-77b4-11ec-9437-dac502259ad0.jpg87702546-77b4-11ec-9437-dac502259ad0.jpg
声明:本文内容及配图由入驻作者撰写或者入驻合作网站授权转载。文章观点仅代表作者本人,不代表电子发烧友网立场。文章及其配图仅供工程师学习之用,如有内容侵权或者其他违规问题,请联系本站处理。 举报投诉
  • IT
    IT
    +关注

    关注

    2

    文章

    793

    浏览量

    63028
收藏 人收藏

    评论

    相关推荐

    安科AEW100

    安科
    jf_20345925
    发布于 :2024年03月14日 15:34:18

    安科医疗IT系列

    智能电表安科
    jf_20345925
    发布于 :2024年03月13日 16:36:15

    安科

    智能电表安科
    jf_20345925
    发布于 :2024年03月13日 16:33:05

    浅谈医疗卫生体制改革背景下能耗分析系统在医院节能工作的实践与探索

    浅谈医疗卫生体制改革背景下能耗分析系统在医院节能工作的实践与探索 张颖姣 安科瑞电气股份有限公司 上海嘉定 201801 摘要:在我国建设资源节约型、环境友好型社会以及深化医药卫生体制
    的头像 发表于 03-11 15:51 105次阅读
    浅谈<b class='flag-5'>医疗</b>卫生体制改革背景下能耗分析系统在<b class='flag-5'>医院</b><b class='flag-5'>节能</b>工作的实践与探索

    浅谈配电节能技术在医院建筑中的应用

    浅谈配电节能技术在医院建筑中的应用 张颖姣 安科瑞电气股份有限公司 上海嘉定 201801 摘要:本文旨在探讨电气节能技术在医院建筑中的应用
    的头像 发表于 02-27 15:15 116次阅读
    浅谈配电<b class='flag-5'>节能</b>技术在<b class='flag-5'>医院</b>建筑中的应用

    浅谈医院基于配电能效管理系统节能减排的实施

    浅谈医院基于配电能效管理系统节能减排的实施 张颖姣 安科瑞电气股份有限公司 上海嘉定 201801 摘要:随着国家节能减排力度的加大,医院
    的头像 发表于 02-27 15:12 136次阅读
    浅谈<b class='flag-5'>医院</b>基于配电能效管理系统<b class='flag-5'>节能</b>减排的实施

    浅谈医院电气能源管理与节能措施分析

    浅谈医院电气能源管理与节能措施分析 张颖姣 安科瑞电气股份有限公司 上海嘉定 201801 摘要:医院建筑工程的电气设计比其他行业的电气设计难度大,因为
    的头像 发表于 02-27 15:11 104次阅读
    浅谈<b class='flag-5'>医院</b>电气能源管理与<b class='flag-5'>节能</b>措施分析

    安科AM系列微机保护装置贵阳万科翡翠滨江配电工程项目的应用

    变电所智能配电系统设计与产品二次原理图集.2020.10月版 [3] 安科用户变电站综合自动化与运维解决方案.2021.11月版
    发表于 02-20 11:01

    安科瑞医用隔离电源系统在江苏某医院项目中的应用

    摘要:介绍该三级乙等综合医院采用安科瑞医用隔离电源系统,使用分体配电柜安装方式,从而实现将TN系统转化为IT系统,以及系统绝缘情况监测。1、概述该医院占地面积4.2万平方米,建筑面积7.14万平方米
    的头像 发表于 09-27 08:09 266次阅读
    <b class='flag-5'>安科</b>瑞医用隔离电源系统在江苏某<b class='flag-5'>医院</b><b class='flag-5'>项目</b>中的应用

    安科医疗建筑能效管理平台助力绿色医院安全地毯运行

    安科
    jf_55193456
    发布于 :2023年09月09日 16:27:01

    安科电量传感器产品介绍

    传感器安科
    jf_55193456
    发布于 :2023年09月08日 16:25:01

    教你如何设置安科医疗告警装置接入系统数?

    多功能电表安科
    jf_55193456
    发布于 :2023年08月19日 12:52:12

    安科用电精灵(二)# #产品方案

    安科
    jf_87134138
    发布于 :2023年06月01日 16:05:42

    安科用电精灵讲解#产品方案 (一)

    安科
    jf_87134138
    发布于 :2023年06月01日 16:02:33

    安科瑞医用隔离电源系统在安徽省某医院项目中的应用

    综合医院。 0概述 该院始建于1953年,前身是原县级人民医院;是一所集医疗、教学、科研、预防保健为一体的国家三级综合性医院。该院占地面积约110亩,建筑面积15.34万平方米,设置床
    的头像 发表于 05-31 15:27 320次阅读
    <b class='flag-5'>安科</b>瑞医用隔离电源系统在安徽省某<b class='flag-5'>医院</b><b class='flag-5'>项目</b>中的应用